Template:Battery Charging
Batteries can be charged using the included battery charger. Look to the instructions included with the charger for how to properly charge your battery and keep them healthy.
Note The batteries should never be discharged below 20V. The batteries are fully charged at 25.2V.
Product Page: Elangears ELAN R X2
Recommended Settings
To safely charge your battery and help keep it healthy, the following settings are recommended.
Note While it takes longer, using the Smart Charge setting on the battery charger helps the battery to last longer by balancing the charge of each cell.
Specifications
Operation Power: DC 11~16V / AC 100~240V (50 / 60Hz)
Output Port: DUAL
Charging Current: CH 1 - 0.1~10A (Max. 120W) / CH 2 - 0.1~15A (Max. 180W) / Extra Power (Max. 10A)
Discharging Current: CH 1 - 0.1~7A (Max. 30W) / CH 2 - 0.1~7A (Max. 30W)
Batteries Available: Li-Po: 1 - 6S / Li-Fe: 1 - 6S / Li-Ion: 1 - 6S / Ni-MH: 1 - 14S / Ni-Cd: 1 - 14S / Pb (Lead): 2 ~ 20V
Size: 178 x 151 x 86mm
Mass: 1.8kg