All dimensions are displayed in millimeters (mm) and degrees.
Please click on any image for a larger version.
Contents |
Mount Block Removal
The mounting block is connected to the Allegro Hand using six (6) M3 flat-head screws (3 on each side).
400px
Remove three (3) screws on either side of the hand.
Do NOT remove the two (2) screws labeled A or the corresponding screws on the other side of the hand.
Note: Secure the hand while unscrewing the mounting block to avoid dropping the hand once disconnected.
Once the six (6) screws have been removed, the mounting block can be removed from the bottom of the hand.
Mounting
The block can be mounted to a surface using six (6) M3 socket-head cap screws.
Note: The hand should be mounted to a raised area so as to avoid thumb-mount interference during hand movement.
Reassembly
Place the hand onto the mounting block and replace the six (6) M3 flat-head screws (3 on each side).