Battery Charging
Batteries can be charged using the included battery charger. Look to the instructions included with the charger for how to properly charge your battery and keep them healthy.
Warning The batteries should never be discharged below 20V. The batteries are fully charged at 25.2V.
Product Page: Elangears ELAN R X2
Recommended Settings
To safely charge your battery and help keep it healthy, the following settings are recommended.
Note While it takes longer, using the Smart Charge setting on the battery charger helps the battery to last longer by balancing the charge of each cell.
Specifications
Operation Power: DC 11~16V / AC 100~240V (50 / 60Hz)
Output Port: DUAL
Charging Current: CH 1 - 0.1~10A (Max. 120W) / CH 2 - 0.1~15A (Max. 180W) / Extra Power (Max. 10A)
Discharging Current: CH 1 - 0.1~7A (Max. 30W) / CH 2 - 0.1~7A (Max. 30W)
Batteries Available: Li-Po: 1 - 6S / Li-Fe: 1 - 6S / Li-Ion: 1 - 6S / Ni-MH: 1 - 14S / Ni-Cd: 1 - 14S / Pb (Lead): 2 ~ 20V
Size: 178 x 151 x 86mm
Mass: 1.8kg
Changing the Batteries
While running on battery power, the battery voltage can be monitored using the LCD Panel Voltage Display on the rear of the dog. The power management system will also actively monitor the battery voltage and notify the user when the battery should be changed.
25.2 - 22.1V No sound - This is the normal operating voltage range.
22.0 - 20.6V Beep (pause) beep (pause)... - It is recommended you change the battery, but you have a few more minutes if necessary.
20.5 - 20.1V Beep beep beep beep... - You must change the battery immediately to avoid damage to the battery. The dog will soon shut down.
20.0 - 0.00V Beeeeeeeeeeeeep... - The power management system will shut down at 20V. Power to the everything is lost.
Note To keep the computer running while swapping batteries, switch just one battery at a time to ensure constant power to the power management system.